Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plan Commission Packet - 9/2/2014
CITY OF MUSKEGO PLAN COMMISSION AGENDA September 2, 2014 6:00 PM Muskego City Hall, W182 S8200 Racine Avenue CALL TO ORDER PLEDGE OF ALLEGIANCE ROLL CALL STATEMENT OF PUBLIC NOTICE APPROVAL OF THE MINUTES OF THE AUGUST 5, 2014 MEETING. NEW BUSINESS FOR CONSIDERATION RESOLUTION #PC 046-2014 - Approval of a Building, Site, and Operation Plan and Certified Survey Map for Taco Bell located in the SE 1/4 of Section 3 and the SW 1/4 of Section 2 (Janesville Road / Tax Key Nos. 2172.030.004 & 2172.030.005). MISCELLANEOUS BUSINESS ADJOURNMENT NOTICE IT IS POSSIBLE THAT MEMBERS OF AND POSSIBLY A QUORUM OF MEMBERS OF OTHER GOVERNMENTAL BODIES OF THE MUNICIPALITY MAY BE IN ATTENDANCE AT THE ABOVE-STATED MEETING TO GATHER INFORMATION; NO ACTION WILL BE TAKEN BY ANY GOVERNMENTAL BODY AT THE ABOVE-STATED MEETING OTHER THAN THE GOVERNMENTAL BODY SPECIFICALLY REFERRED TO ABOVE IN THIS NOTICE. ALSO, UPON REASONABLE NOTICE, EFFORTS WILL BE MADE TO ACCOMMODATE THE NEEDS OF DISABLED INDIVIDUALS THROUGH APPROPRIATE AIDS AND SERVICES. FOR ADDITIONAL INFORMATION OR TO REQUEST THIS SERVICE, CONTACT MUSKEGO COMMUNITY DEVELOPMENT DEPARTMENT, (262) 679-4136. Unapproved CITY OF MUSKEGO PLAN COMMISSION MINUTES August 5, 2014 6:00 PM Muskego City Hall, W182 S8200 Racine Avenue CALL TO ORDER PLEDGE OF ALLEGIANCE ROLL CALL STATEMENT OF PUBLIC NOTICE APPROVAL OF THE MINUTES OF THE JULY 1, 2014 MEETING. CONSENT BUSINESS Recommended for approval en gross. Commissioner Buckmaster made a motion to approve Consent Business engross. Commissioner Hulbert seconded. Motion Passed 5 in favor. RESOLUTION #PC 044-2014 - Approval of a Two Lot Extraterritorial Certified Survey Map for the Fuller property located in the Town of Vernon. RESOLUTION #PC 045-2014 - Approval of a Second Accessory Structure for the Rogers property located in the NW 1/4 of Section 4 (Tax Key No. 2174.077 / S66 W18560 Jewel Crest Drive). NEW BUSINESS FOR CONSIDERATION RESOLUTION #PC 043-2014 - Recommendation to Council to Amend the Zoning Map and 2020 Comprehensive Plan of the City of Muskego for Ener-Con Companies for properties located in the SE 1/4 of Section 9 (Tax Key Nos. 2195.999, 2193.970.028, 2193.970.029 / Janesville Road). Commissioner Stinebaugh made a motion to approve RESOLUTION #PC 043-2014 - Recommendation to Council to Amend the Zoning Map and 2020 Comprehensive Plan of the City of Muskego for Ener-Con Companies for properties located in the SE 1/4 of Section 9 (Tax Key Nos. 2195.999, 2193.970.028, 2193.970.029 / Janesville Road). Commissioner Buckmaster seconded. Motion Failed 0 in favor 5 opposed. MISCELLANEOUS BUSINESS ADJOURNMENT Alderman Wolfe made a motion to adjourn at 7:25 PM. Commissioner Hulbert seconded. Motion Passed 5 in favor. Respectfully submitted, Kellie McMullen, Recording Secretary City of Muskego Plan Commission Supplement PC 046-2014 For the meeting of: September 2, 2014 REQUEST: Building Site and Operation Plans and Certified Survey Map for Taco Bell. Tax Key No. 2172.030.004 & 2172.030.005 (Janesville/Moorland) SE ¼ of Section 3 and SW ¼ of Section 2 PETITIONER: Sundance, Inc. INTRODUCED: September 2, 2014 LAST AGENDA: N/A PREPARED BY: Jeff Muenkel, AICP BACKGROUND PC 046-2014 Petitioners have submitted Building, Site and Operation plans and a 2-Lot Certified Survey Map to construct a 2,439 square foot building for Taco Bell along Janesville Road and Princeton Drive. PLAN CONSISTENCY PC 046-2014 Comprehensive Plan: The 2020 Plan depicts the areas for commercial use. The proposal is consistent with the Plan. Zoning: The property is currently zoned PD-37 (Candlewood Village Planned Development District) and B-2 (Local Service Center). The proposal is consistent with the current zoning requirements for commercial uses. Park and Open Space Plan: No acquisitions are proposed in this area. The proposal is consistent with the Plan. Conservation Plan: No acquisition or management priorities are depicted in this area. The proposal is consistent with the Plan. Street System Plan: Janesville Road and Princeton Drive were previously dedicated. The proposal is consistent with the Plan. Adopted 208 Sanitary Sewer Service Area: Public sanitary sewer serves the property. The proposal is consistent with the Plan. Water Capacity Assessment District: The property is served by public water service. The proposal is consistent with the Plan. Stormwater Management Plan: Stormwater is already accounted for in existing regional stormwater ponds in the area. The proposal is consistent with the Plan. Design Guides The Moorland Corridor South Design Guide governs this area. The proposal appears to meet the requirements of the guide well and this is discussed in more detail below. DISCUSSION PC 046-2014 The submittal is included in the supplement consisting of a narrative, site/grading plans, building elevations, colored renderings, landscape plans, photometric plans, and lighting details. As stated above, the petitioner requests approvals for a Taco Bell along Janesville Road. The proposed building will be 2,439 square feet situated on a 1.9 acre site. CSM The petitioner is proposing to adjust the lot lines by Certified Survey Map leaving two (2) parcels. The lots will range in size from 51,956 sq. ft. (1.19 acres) to 71,877 sq. ft. (1.65 acres). Upon review of the CSM, the bulk requirements of the code appear to be met. There are some minor technical corrections that need to occur that will need to be addressed before the CSM can be signed by the City and recorded. Building, Site and Operation Plan Architecture The architecture shows varying detail of materials and colors used throughout the facades of the structure. Masonry, stucco, and various metal panel products are used creating a variety of detail on the building which is similar to the modern type of architecture used on th e neighboring Wal-Mart. The landscape plan aids in complimenting the structure and making each façade well presentable. This area of the City is governed by the General Design Guide and the Moorland Corridor South Design Guide. The General Design Guide calls for 50% masonry product and the proposed structure shows 100% masonry other than the various metal accents. The Moorland Corridor South Design Guide calls for architecture with Prairie and/or Craftsman influences. The proposed building adapts to th e Moorland South Design Guide well using multiple types of materials, creating horizontal lines, utilizing decorative brackets along the roof coping, tapering columns, utilizing standing seam gabeled roofs, and using windows with horizontal mullions. The building materials used consist of the following below and the colors can be found on the various colored renderings provided: Light and Dark Faced Brick Stone Veneer Aluminum Storefronts and Entrance Windows Standing Seam Metal Roofs and Parapets Prefinished Metal Copings and Fascia Site Plan, Access, and Parking The 1.19 acre site is vacant and pad-ready for development today. The building is surrounded by parking with ample access to a drive thru lane and the building is surrounded by easily accessible walkways and a pleasing outdoor patio/green area for patrons. Vehicular access meets code throughout the site as two-way drive aisles at least 24 feet in width and one-way aisles at least 12 feet in width. Vehicular access to the site is shown to occur in one access point off of Princeton Drive. The access off of Princeton Drive will be surrounded by a cross access easement that is shown on the CSM that will ensure a future access for an owner to the parcel to the west as well as lessen the access points along Princeton Drive. Parking is shown as 26 stalls all meeting the city code dimensions of 10’x20’. The amount of parking stalls provided meets typical code requirements for a restaurant facility of this type as Muskego typically ensures that 2 stalls are required per 100 SF of customer floor area. The building has 727 SF of customer floor area, which would require 15 stalls usually. Operations Taco Bell shows in the narrative that the open hours of the lobby are intended to be from 7am -10pm daily. While the drive thru will be open longer with hours of 7am -4am Thursday thru Saturday and 7am - 2am Sunday thru Wednesday. They will have up to 50 interior seats along with 4 exterior tables on the patio. A drive thru service will be found along the full eastern portion of the structure. The estimated daily customers are expected to be around 175 and will employ a total of 25 people. One item that isn’t mentioned in the supplement is in regards to truck deliveries and refuse pickups. Due to residential uses across the street the resolution is worded that any refuse pickups and truck deliveries must be between the hours of 8am -6pm. Fire Department Approval The site plan is still subject to Fire Department approvals at the time of building permits as well. Possible changes to the site plan may be required based upon the final Fire Department review, however, the plan appears to address the needed fire lane requirements well. Refuse Enclosure A very large dumpster enclosure is proposed along the south portion of the site and the enclosure is to be constructed as a brick embossed concrete poured wall that is colored to match the principal structure . Usually, Plan Commission likes to see these structures constructed of similar materials to the overall structure. Due to the enclosure being so large and past PC approvals staff has worded the resolution that the dumpster enclosure is instead constructed of the brick or stone that is part of the principal structure and not the brick embossed concrete poured wall. Landscaping A landscape plan has been submitted as part of the proposal. Review of the landscape plan is pending and the City Forester will work with the petitioner based upon any changes/additions that are needed. In all, a wealth of landscaping is proposed and a nice outdoor seating area and green area is proposed on the north façade side along Janesville Road. Staff has included in the resolution to include a tree along the SW corner of the property next to the entrance. Also, to ensure proper screening for the homes across Princeton Drive, the resolution includes a statement that the petitioner shall offer to plant various coniferous trees (matching those existing) on the south side of Princeton Drive in order to aid in screening of the homes here from future headlights. Signage Signage is part of the submittal and is shown to be two monument signs with one along Janesville Road and one along Princeton Drive, wall signage on all facades, and various site identification signage (directional and drive thru signage) and all signage proposed appears to meet code requirements but will be subject to future staff approvals at building permit time. Lighting A photometric plan has been submitted and shows appropriate lighting levels per code on the site. Site lighting is proposed as approximately nine (9) LED polelights and various structure cylindrical LED wall sconces. Polelights are to have a 6-inch concrete base and be 18 feet in height all matching city code requirements. Lighting details and photometrics show th at all City of Muskego requirements are being met. Sewer, Water, Storm, Grading The development will be served by existing public sanitary sewer and water. Further, all stormwater arrangements have been accommodated for on existing regional ponds in the area. Other The following is also part of the Plan Commission resolution: BE IT FURTHER RESOLVED, The site plan is still subject to Fire Department approvals at the time of building permits. BE IT FURTHER RESOLVED, That any bollards must be painted to match the colors of the principal structure. BE IT FURTHER RESOLVED, That any new handicap signs be incorporated and bored into the ground. BE IT FURTHER RESOLVED, That all roof top and ground mechanicals (including HVAC devices, electrical transformers, etc.) must be screened from view and/or incorporated into the design of the site/structure (screening, etc.) and should be approved by the Community Development Department. Roof top mechanicals must be screened with the same main architectural materials found on the main building. STAFF RECOMMENDATION PC 046-2014 Approval of Resolution PC 046-2014. MUSK EG Othe City of Ar ea o f Inte restI0100200 Fee t Ag en da Item(s) Pr op er tie s Zon in g D istr ic ts Rig ht -o f-Way Hy dr og rap hy Supp lem ental MapRESOLUTION #PC 04 6-2014 Ta co Be ll Ja nes ville R oad / Mo or land Rd J A N E S V I L L E L O O M I S R D RA CIN E AV DURHAM W O O D S CO LL EG E Pre p ar ed b y C ity o f Mu ske g o P la n n in g D e p ar tm e nt Da te : 8 /2 6/2 0 14 RESOLUTION #P.C. 046-2014 APPROVAL OF A BUILDING SITE AND OPERATION PLAN AND CERTIFIED SURVEY MAP FOR TACO BELL LOCATED IN THE SE ¼ OF SECTION 3 AND THE SW ¼ OF SECTION 2 (JANESVILLE ROAD / TAX KEY NOS. 2172.030.004 & 2172.030.005) WHEREAS, On August 18, 2014 Building, Site and Operation Plans and a Certified Survey Map for Taco Bell were submitted located in the SE ¼ of section 3 and the SW ¼ of section 2 (Tax Key Nos. 2172.030.004 & 2172.030.005 / Janesville Road), and WHEREAS, The proposal is to build a Taco Bell restaurant totaling 2,439 square feet situated on a proposed 1.19 acre site, and WHEREAS, The 2020 Comprehensive Plan already identifies this area for commercial land use, and WHEREAS, The existing PD-37 and B-2 zoning districts require a minimum lot size of 20,000 sq ft and average lot width of 100’ per commercial lot, and WHEREAS, The CSM shows two parcels varying in size from 51,956 sq. ft. (1.19 acres) to 71,877 sq. ft. (1.65 acres), and WHEREAS, The architecture shown in the various colored renderings provided as part of the submittal show varying detail of materials and colors used throughout the facades of the structure, and WHEREAS, This area of the City is governed by the Moorland Corridor South Design Guide and the guide calls for 50% masonry product and architecture with Prairie and/or Craftsman influences, and WHEREAS, The proposed structure shows 100% masonry other than the various metal accents, and WHEREAS, The building materials used consist of the following below and the colors can be found on the various colored renderings provided: Light and Dark Faced Brick Stone Veneer Aluminum Storefronts and Entrance Windows Standing Seam Metal Roofs and Parapets Prefinished Metal Copings and Fascia WHEREAS, The proposed building adapts to the Moorland South Design Guide well using multiple types of materials, creating horizontal lines, utilizing decorative brackets along the roof coping, tapering columns, utilizing standing seam gabeled roofs, and using windows with horizontal mullions, and WHEREAS, The building sits lower compared to passersby on Janesville Road which may result in seeing the back of the parapet walls on the roofline and these walls will be built with the main materials used on each side, and WHEREAS, The one acre site is vacant and pad-ready for development today, and WHEREAS, The building is surrounded by parking with ample access to a drive thru lane and the building is surrounded by easily accessible walkways and an outdoor patio/green area for patrons, and WHEREAS, Vehicular access meets code throughout the site as two-way drive aisles are at least 24 feet in width and one-way aisles are at least 12 feet in width, and WHEREAS, Vehicular access to the site is shown to occur in one access point off of Princeton Drive, and WHEREAS, The access off of Princeton Drive will be surrounded by a cross access easement that is shown on the CSM that will ensure a future access for an owner to the parcel to the west as well as lessen the access points along Princeton Drive, and WHEREAS, Parking is shown as 26 stalls all meeting the city code dimensions of 10’x20’, and WHEREAS, The amount of parking stalls provided meets typical code requirements for a restaurant facility of this type as Muskego typically ensures that 2 stalls are required per 100 SF of customer floor area, and WHEREAS, The building has 727 SF of customer floor area, which would usually require 15 stalls, and WHEREAS, The site and building plans are subject to Fire Department approvals and the submittal appears to show proper Fire Access Lanes, and WHEREAS, A dumpster enclosure is proposed along the south portion of the site and the enclosure is to be constructed as a brick embossed concrete poured wall that is colored to match the principal structure, and WHEREAS, A landscape plan has been submitted as part of the proposal showing ample plantings and a few extra plantings may be required along the entrance off of Princeton Drive for increased screening to homes here, and WHEREAS, Signage is part of the submittal and is shown to be two monument signs with one along Janesville Road and one along Princeton Drive, wall signage on all facades, and various site identification signage (directional and drive thru signage) and all signage proposed appears to meet code requirements but will be subject to future staff approvals at building permit time, and WHEREAS, A photometric plan has been submitted and shows appropriate lighting levels per code on the site, and WHEREAS, Site lighting is proposed as approximately nine (9) LED polelights and various structure cylindrical LED wall sconces, and WHEREAS, Polelights are to have a 6-inch concrete base and be 18 feet in height all matching city code requirements, and WHEREAS, The development will be served by existing public sanitary sewer and water, and WHEREAS, All stormwater arrangements have been accommodated for on existing regional ponds in the area, and WHEREAS, The open hours of the lobby are intended to be from 7am-10pm daily with the drive thru open from 7am-4am Thursday thru Saturday and 7am-2am Sunday thru Wednesday, and THEREFORE BE IT FURTHER RESOLVED, That the Plan Commission approves of Building, Site and Operation Plans and a Certified Survey Map for Taco Bell located in the SE ¼ of section 3 and the SW ¼ of section 2 (Tax Key Nos. 2172.030.004 & 2172.030.005 / Janesville Road). BE IT FURTHER RESOLVED, That the dumpster enclosure is instead constructed of the brick or stone that is part of the principal structure and not the brick embossed concrete poured wall. BE IT FURTHER RESOLVED, That any refuse pickups and truck deliveries must be between the hours of 8am-6pm. BE IT FURTHER RESOLVED, The site plan is still subject to Fire Department approvals at the time of building permits. BE IT FURTHER RESOLVED, That the landscape plan shall include a tree along the SW corner of the property next to the entrance and that the petitioner shall offer to plant various coniferous trees (matching those existing) on the south side of Princeton Drive in order to aid in screening of the homes here. BE IT FURTHER RESOLVED, That the existing coniferous trees up along Janesville Road can be removed if replacements are found on the new landscape plan. BE IT FURTHER RESOLVED, A final landscape plan will need to be approved by the City Forester prior to the issuance of building permits. BE IT FURTHER RESOLVED, That any bollards must be painted to match the colors of the principal structure. BE IT FURTHER RESOLVED, That any new handicap signs be incorporated and bored into the ground. BE IT FURTHER RESOLVED, That all roof top and ground mechanicals (including HVAC devices, electrical transformers, etc.) must be screened from view and/or incorporated into the design of the site/structure (screening, etc.) and should be approved by the Community Development Department. Roof top mechanicals must be screened with the same main architectural materials found on the main building. BE IT FURTHER RESOLVED, That the CSM is subject to resolution of technical discrepancies as identified by the City Engineers, and payment of all applicable fees in Section 18.14(3) of the Land Division Ordinance and outstanding assessments if applicable. BE IT FURTHER RESOLVED, That all technical corrections from the City on the CSM will need to be addressed before the Certified Survey Map can be signed and recorded. BE IT FURTHER RESOLVED, That a digital file of this CSM shall be submitted to the City in accordance with Common Council Ordinance No. 1118 and Resolution 196-2002. BE IT FURTHER RESOLVED, That a copy of said plans be kept on file in the Building Department and that all aspects of this plan shall be maintained in perpetuity unless otherwise authorized by the Plan Commission. BE IT FURTHER RESOLVED, That failure to comply with the approval contained in this resolution shall result in the imposition of fines of $100 per day, the initiation of legal action, or both. Plan Commission City of Muskego Adopted: Defeated: Deferred: Introduced: September 2, 2014 ATTEST: Kellie McMullen, Recording Secretary OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 PRELIMINARY SHEET DATES: JULY 8, 2014 JULY 15, 2014 JULY 31, 2014 AUGUST 18, 2014 Lot 2 and 3 of Certified Survey Map Number 10776 filed in Volume 104 of Certified Survey Maps on Page 162-165 as Document Number 3742112; OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 PRELIMINARY SHEET DATES: AUGUST 18, 2014 PRELIMINARY SHEET DATES: AUGUST 18, 2014 OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 EL. 0'-0" TOP OF SLAB EL. 18'-9 1/2" TOP OF PLATE LINE OF SIGHT 1/8" = 1'-0"A OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 PRELIMINARY SHEET DATES: LS1.0 AUGUST 15, 2014 PRELIMINARY SHEET DATES: AUGUST 18, 2014 AUGUST 19, 2014 AUGUST 22, 2014 OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 ECOFORM OUTDOOR SITE & AREA PHILIPS GARDCO, LED SITE & AREA LUMINAIRE, ECOFORM The Philips Gardco EcoForm combines economy with performance in an LED area luminaire. Capable of delivering up to 20,000 lumens or more in a compact, low profile LED luminaire, EcoForm offers a new level of customer value. EcoForm features an innovative retrofit arm kit, simplifying site conversions to LED by eliminating the need to drill additional holes in most existing poles. Integral control systems available for further energy savings. Redefining value with outstanding performance Project: Location: Catalog No: Fixture Type: Mfg: Qty: Notes: G200-047 08/13 page 1 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires Ordering guide Prefix Mounting Optics LED Array & LED Wattage LED Selection Voltage Finish Options ECF EcoForm Standard Luminaire ECF-DIM EcoForm with 0-10V Dimming ECF-APD1 EcoForm with Auto Profile Dimming ECF-MR502 EcoForm with Motion Response at 50% low Pole mounted sensor ECF-APD-MRO2 EcoForm with Auto Profile Dimming and Motion Response Override Pole mounted sensor ECF-MRI2,4 EcoForm with Motion Response at 50% low Luminaire mounted sensor ECF-APD-MRI2,4 EcoForm with Auto Profile Dimming with Motion Response Override Luminaire mounted sensor 1 Single 2 2@180 2@90 2@90 3 3@90 3@120 3@120 4 4@90 WS Wall mount including Surface conduit Rear entry permitted MA Mast Arm Fitter (requires 2-3/8" O.D. Mast Arm) 2 Type 2 3 Type 3 4 Type 4 5 Type 5 530 mA 55LA-32531 75LA-4853 100LA-6453 700mA 70LA-3270 105LA-4870 135LA-6470 1050mA 105LA-321A1 160LA-481A 215LA-641A CW 5,700K 70 CRI NW 4,000K 70 CRI WW3 3,000K 70 CRI UNV 120-277V HVU 347-480V 120 208 240 277 347 480 BRP Bronze Paint BLP Black Paint WP White Paint NP Natural Paint OC Optional Color Specify optional color or RAL ex: OC-LGP or OC-RAL7024. SC Special Color Specify. Must supply color chip. Requires factory quote. TL Tool-Less entry & driver removal hardware TB4 Terminal Block IS5 Internal Shield LF6,10 Line Fusing LFC6,10 Line Fusing for Canada PCR Photocell Receptacle Only PC6,7,10 Receptacle with Photocell PCB6,7,10 Photocell Button RAM Retrofit Arm Mount Kit PTF28 Pole Top Fitter for 2-3/8"-3" Tenon PTF38 Pole Top Fitter for 3"-3.5" Tenon PTF48 Pole Top Fitter for 3.5"-4" Tenon RPA9 Round Pole Adaptor for 3" to 3.9" OD BD Bird Deterrant (field installed only) 1. Available in 120V thru 277V only. 4. ECF-MRI requires outboarded sensor 6. Voltage must be specified. 9. No adaptor required for 4" round poles. 2. Available in 120V or 277V only. when used with Terminal Block (TB) option. 7. Not available in 480V. RPAs provided with Black Paint standard. 3. Contact factory for lead times on warm white. 5. Not available with Type 5 optics. 8. Not available in 3 @ 120. 10. Not available with UNV (120-277V). ® ECF EcoForm Standard Luminaire 1 Single 4 Type 4 1050mA 215LA-641A NW 4,000K 70 CRI UNV 120 -277V BRP Bronze RAM Retrofit Arm Mount Kit IS5 Internal Shield Taco Bell Muskego,WI ECF-1-4-215LA-641A-N ECF 1 4 215LA NW UNV BRP RAM, IS ECOFORM OUTDOOR SITE & AREA G200-047 08/13 page 2 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires LED Wattage and Lumen Values - Standard EcoForm Luminaire EcoForm Drill Template (Standard Arm Mount) Initial Lumens12 Order Code (standard units) Array Quantity Total LEDs LED Current (mA) Average System Watts11 LED Selection 2 Type 2 3 Type 3 4 Type 4 5 Type 5 55LA-3253 2 32 530 52 NW 5,994 (s)5,895 (s)5,823 (s)5,588 (s) 75LA-4853 348530 77NW8,899 (s)8,753 (s)8,646 (s)8,297 (s) 100LA-6453 464530 103NW11,896 (s)11,700 11,558 11,091 70LA-3270 232700 69 NW7,385 (s)7,576 (s)7,293 (s)7,068 (s) 105LA-4870 348700 104NW10,965 (s)11,249 (s)10,828 (s)10,494 (s) 135LA-6470 464700 139NW14,657 (s)15,037 14,475 (s)14,028 105LA-321A 2321050107NW10,199 (s)10,458 10,072 (s)9,767 160LA-481A 3481050158NW15,144 (s)15,565 14,955 (s)14,465 215LA-641A 4 64 1050 211 NW 20,243 20,252 19,991 19,880 11. System input wattage may vary based on input voltage, by up to +/- 10% , and based on manufacturer forward voltage, by up to +/- 8%. 12. Lumen values based on photometric tests performed in compliance with IESNA LM-79. (s). Data is scaled based on tests of similar, but not identical, luminaires. Accessories (Order Separately) FS1R-100 MR hand held programmer (For use with 'MRI' motion response when field programming is required). If desired, only one is needed per job. MS-A-120V 120V input - Motion Sensor for MR50 or APD-MRO MS-A-277V 277V input - Motion Sensor for MR50 or APD-MRO 1.00” 2.54 cm 2.50” 6.35 cm 2.0” 5.08 cm Ø 0.41” 1.04 cm Ø 0.875” 2.22 cm Note: For reference only. Drawing not to scale. 215LA-641A 4 64 1050 211 NW 19,991 ECOFORM OUTDOOR SITE & AREA G200-047 08/13 page 3 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires Dimensions - Standard EcoForm Luminaire Dimensions - EcoForm with Mast Arm Fitter (MA) Dimensions - EcoForm with Wall Mount (WS) Dimensions - EcoForm with Retrofit Arm Mount (RAM) 13” 33 cm 3.3” 8.38 cm 2.1” 5.3 cm 1.3” 3.3 cm 24.2” 61.47 cm 2.5” 6.35 cm 24.2” 61.47 cm 6.1” 15.5 cm Top View Top View Top View Top View Side View Side View Side View Side View End View End View End View End View 2.2” 5.58 cm 26” 66.04 cm 23.8” 60.45 cm 6.6” 16.76 cm 13” 33.02 cm 6.6” 16.76 cm 3.3” 8.38 cm Approximate Luminaire Weight: 20 Lbs (9.07 Kg) Approximate Luminaire Weight: 21 Lbs (9.53 Kg) Approximate Luminaire Weight: 21.5 Lbs (9.77 Kg) Approximate Luminaire Weight: 23.36 Lbs (10.6 Kg) Single Twin (2@180) 3/4@90 0.2 / 0.019 0.5 / 0.046 0.5 / 0.046 Single Twin (2@180) 3/4@90 0.3 / 0.028 0.6 / 0.056 0.7 / 0.065 Single 0.51 / 0.047 26.2” 66.55 cm 26.2” 66.55 cm 3.3” 8.4 cm 3.23” 8.2 cm 1.5” 3.8 cm 2.0” 5.1 cm 6.5” 16.5 cm 6.5” 16.5 cm 6.5” 16.5 cm 8.1” 20.57 cm 13” 33 cm 13” 33 cm 31.5” 80.01 cm 31.5” 80.01 cm 7.7” 19.56 cm 3.3” 8.4 cm 3.3” 8.38 cm 2.1” 5.3 cm 13.4” 34.04 cm 2.9” 7.4 cm EPA (Ft 2/M2) EPA (Ft 2/M2) EPA (Ft 2/M2) EPA (Ft2/M2) 0.3 / 0.028 ECOFORM OUTDOOR SITE & AREA G200-047 08/13 page 4 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires Black, 120V OR 277V Input White - Neutral Sensor Red Connects to Override Input (Orange) Line of DynaDimmer ECF Philips Gardco EcoForm LED standard luminaire providing constant wattage and constant light output when power to the luminaire is energized. ECF-DIM Philips Gardco EcoForm LED luminaire provided with 0-10V dimming for connection to a control system provided by others. ECF-APD Philips Gardco EcoForm LED luminaire with Automatic Profile Dimming. Luminaire is provided with a Philips DynaDimmer module, programmed to go to 50% power, 50% light output two (2) hours prior to night time mid-point and remain at 50% for six (6) hours after night time mid-point. Mid-point is continuously recalculated by the Philips DynaDimmer module based on the average mid-point of the last two full night cycles. Short duration cycles, and power interruptions are ignored and do not affect the determination of mid-point. ECF-APD is available in 120V through 277V input only. ECF-APD Dimming Profile: ECF-MR50 Philips Gardco EcoForm LED luminaire with motion response, providing a 50% power reduction on low and a commensurate reduction in light output. The power and light output reduction is accomplished utilizing the Philips DynaDimmer module, programmed for a constant 50% power. Power supplied by the motion sensor connected to the override line on the DynaDimmer takes the luminaire to high setting, 100% power and light output, when motion is detected. The luminaire remains on high until no motion is detected for the motion sensor duration period, after which the luminaire returns to low. Duration period is factory set at 15 minutes, and is field adjustable from 5 minutes up to 15 minutes. ECF-MR50 is available in 120V through 277V input only to the luminaire. Motion sensors require single voltage 120V or 277V input. The Area PIR motion sensor is the WattStopper EW-200-120-W (120V Input - MSA- 120V) or the WattStopper EW-200-277-W (277V Input - MSA-277V.) One motion sensor per pole is required and is ordered separately. Area sensors require single voltage 120V or 277V input. The area motion detector provides coverage equal to up to 6 times the sensor height above ground, 270° from the front-center of the sensor. Area PIR Motion Sensor Coverage Pattern: Motion response requires that the pole include an additional hand hole 15 feet above the pole base, normally oriented 180° to the standard hand hole. For Philips Gardco poles, order the pole with the Motion Sensor Mounting (MSM) option which includes the hand hole and a special hand hole cover plate for the sensor with a 1/2" NPT receptacle centered on the hand hole cover plate into which the motion sensor mounts. Once the motion sensor is connected to the hand hole cover plate, then wiring connections are completed in the pole. The plate (complete with motion sensor attached and wired) is then mounted to the hand hole. If poles are supplied by others, the customer is responsible for providing suitable mounting accommodations for the motion sensor in the pole. ECF-APD-MRO Philips Gardco EcoForm LED luminaire with Automatic Profile Dimming, with Motion Response Override. The ECF-APD-MRO combines the benefits of both automatic profile dimming and motion response, using the Philips DynaDimmer module. The luminaire will dim to 50% power, 50% light output, per the dimming profile shown for the ECF-APD. If motion is detected during the time that the luminaire is operating at 50%, the luminaire returns to 100% power and light output. The luminaire remains on high until no motion is detected for the duration period, after which the luminaire returns to low. Duration period is factory set at 15 minutes, and is field adjustable from 5 minutes up to 15 minutes. NOTES: ECF-APD-MRO is available in 120V through 277V input only to luminaire. The motion sensor requires either 120V or 277V input to the motion sensor. The ECF-APD-MRO has the same pole requirements and utilizes the same motion sensors as the ECF-MR50. The motion sensor mounts and wires identically as well. The ECF-APD-MRO utilizes the identical dimming profile as shown for the ECF-APD. By combining the benefits of automatic profile dimming and motion response, the ECF-APD-MRO assures maximum energy savings, and insures that adequate light is present if motion is detected. All motion sensors utilized consume 0.0 watts in the off state. Luminaire Configuration Information 100% 100% 50% 50% Power On Mid Point 2 Hours 6 Hours Power Off 90° 9.5ft (3m) 25ft (8m) 52.5ft (16m) 8ft (2.4m) 90° 1H Height 6H3H Distances are approximate. H= Height Above Ground 270° Front Coverage Additional Hand Hole 15' Above Pole Base (oriented 180° to the standard hand hole) Motion Sensor Cover Plate with 1/2" NPT Coupling (supplied with pole) Wiring in Pole Attach Motion Sensor to Cover Plate coupling, Complete Wiring in Pole and Attach Cover Plate to Hand Hole Mounting to a Philips Gardco Pole ECOFORM OUTDOOR SITE & AREA G200-047 08/13 page 5 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires ECF-MRI Luminaires with Motion Response include a LED driver and an integral programmable motion sensor. The motion sensor is set to a constant 50%. When motion is detected, the luminaire goes to 100%. The luminaire remains on high until no motion is detected for the motion sensor duration period, after which the luminaire returns to low. Duration period is factory set at 5 minutes. Available with 120V or 277V only. Luminaires include a passive infrared (PIR) motion sensor, WattStopper® FSP-211 equipped with an FSP-L3 lens, capable of detecting motion within 20 feet of the sensor, 180° around the luminaire, when placed at a 20 foot mounting height, or mounted on a wall. Available in 120V or 277V input only. Motion sensor off state power is 0.0 watts. The approximate motion sensor coverage pattern is as shown below. ECF-APD- MRI Luminaires with Automatic Profile Dimming and Motion Response Override combine the benefits of both automatic profile dimming and motion response. APD-MRI luminaires utilize Philips DynaDimmer. The luminaire will dim to 50% power, 50% light output, per the dimming profile shown for APD luminaires (see page 4). If motion is detected during the time that the luminaire is operating at 50%, the luminaire goes to 100% power and light output. The luminaire remains on high until no motion is detected for the duration period, after which the luminaire returns to low. Duration period is factory set at 5 minutes. APD-MRI luminaires are available with 120V or 277V input voltages only. APD-MRI luminaires use the identical motion sensor as MRI luminaires. See motion sensor details for ECF-MRI. FS1R-100 Wireless Remote Programming Tool The FS1R-100 Remote Programming Tool accessory permits adjustment of ECF-MRI and ECF-APD-MRI sensor settings, including duration and dimming level on low, without the need to connect any wires to the luminaire. The FS1R-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211. It provides wireless access to the FSP-211 sensors for setup and parameter changes. The FS1R-100 display shows menus and prompts to lead you through each process. The navigation pad provides a familiar way to navigate through the customization fields. Within a certain mounting height of the sensor, the FS1R-100 allows modification of the system without requiring ladders or tools simply with a touch of a few buttons. The FS1R-100 IR transceiver allows bi-directional communication between the FSP-211 and the FS1R-100 programming tool . Simple menu screens let you see the current status of the system and make changes. It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more. With the FS1R-100 you can also establish and store FSP-211 parameter profiles. The FS1R-100 operates on three standard 1.5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries. The battery status displays in the upper right corner of the display. Three bars next to BAT= indicates a full battery charge. A warning appears on the display when the battery level falls below a minimum acceptable level. To conserve battery power, the FS1R-100 automatically shuts off 10 minutes after the last key press. You navigate from one field to another using (up) or (down) arrow keys. The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background.) Once active, use the Select button to move to a menu or function within the active field. Value fields are used to adjust parameter settings. They are shown in “less- than/greater-than” symbols: <value>. Once active, change them using (left) and (right) arrow keys. In general the up key increments and the down key decrements a value. Selections wrap-around if you continue to press the key beyond maximum or minimum values. Moving away from the value field overwrites the original value. The Home button takes you to the main menu. The Back button can be thought of as an undo function. It takes you back one screen. Changes that were in process prior to pressing the key are lost.More information on the FS1R-100 Remote Programming Tool is available at wattstopper.com. Luminaire Configuration Information (Continued) Top Coverage PatternSide Coverage Pattern 1H 2H 2H Distances are approximate. H = Height above ground. FSP-201 FSP-211 FD-101 FD-301 Home/Main Menu Up Select Down Right/NextLeft Back Power On/Off BAT= ECOFORM OUTDOOR SITE & AREA G200-047 08/13 page 6 of 6 © 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires General Description The Philips Gardco EcoForm combines economy with performance in an LED area luminaire. Capable of delivering up to 20,000 lumens or more in a compact, low profile LED luminaire, EcoForm offers a new level of customer value. Integral control systems including motion response are available for further energy savings during off peak hours. Housing One piece die cast aluminum housing with integral arm and separate,self retained hinged, one piece die cast door frame. IP Rating LED light engine rated IP66. Vibration Resistance EcoForm with Standard Arm carries a 3G vibration rating that conforms to standards set forth by ANSI C136.31. Testing includes vibration to 3G acceleration in three axes, all performed on the same luminaire. Electrical Driver efficiency (>90% standard). 120-480V available (restrictions apply). Open/short circuit protection. Optional 0-10V dimming to 10% power. RoHS compliant. Surge protector standard. 10KA per ANSI/ IEEE C62.41.2. LED Board and Array 32, 48, or 64 LEDs. Color temperatures: 3000K, 4000K, 5700K +/- 250K. Minimum CRI of 70. Aluminum metal clad board. RoHS compliant. Energy Saving Benefits System efficacy up to 95 lms/W with significant energy savings over Pulse Start Metal Halide luminaires. Optional control options provide added energy savings during unoccupied periods. Motion Sensors ECF-MR50, ECF-APD-MRO, ECF-MRI, ECF-APD- MRI luminaires may be specified for additional energy savings during unoccupied periods. See pages 4-6 for complete details. LED Thermal Management The housing design allows the one piece housing to provide excellent thermal management critical to long LED system life. Optical Systems Type 2, 3, 4, and 5 distributions available. Internal Shield option mounts to LED optics and is available with Type 2, 3, and 4 distributions to control backlight. Mounting Standard luminaire arm mounts to 4" round poles. Square pole adapter included with every luminaire. Round Pole Adapter (RPA) required for 3-3.9" poles. Retrofit Arm Mount EcoForm features an innovative retrofit arm kit. When specified with the retrofit arm (RAM) option, EcoForm seamlessly simplifies site conversions to LED by eliminating the need for additional pole drilling on most existing poles. RAM will be boxed separately. Listings ETL/cETL listed to the UL 1598 standard, suitable for Wet Locations. Suitable for use in ambients from -30° to 40°C (-22° to 104°F). The quality systems of this facility have been registered by UL to the ISO 9001 series standards. All EcoForm luminaires equipped with NW and CW are DesignLights Consortium® qualified. Finish Each standard color luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard colors include bronze (BRP), black (BLP), white (WP), and natural aluminum (NP). Consult factory for specs on optional or custom colors. Warranty EcoForm luminaires feature a 5 year limited warranty. Philips Gardco LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED Drivers also carry a 5 year limited warranty. Motion sensors are covered by warranty for 5 years by the motion sensor manufacturer. Specifications 5.1875” 13.18 cm 2.375” 6.03 cm 2 6. LED Performance: PREDICTED LUMEN DEPRECIATION DATA13 Ambient Temperature °C Driver mA Calculated L70 Hours13,14 L70 Per TM-2114,15 Lumen Maintenance % @ 60,000 hours Up to 40 °C Up to 1050 mA > 350,000 Hours > 60,000 Hours 97% 13. Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions. 14. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. 15. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours. STEEL POLE SHAFT SPECIFICATIONS POLE SHAFT TENON MOUNT STANDARD STYLES: **OTHER SIZES AVAILABLE- SEE ACCESSORIES SECTION** TENON MOUNT STYLES ANCHOR BOLT DIMENSIONS ANCHOR BOLT DIA. (IN.) ANCHOR BOLT LENGTH (IN.) 0.75 PER SCHEDULE BOLT CIRCLE (IN.) BASE PLATE DIM. (IN.) BOLT HOLE (IN.) PLATE THICKNESS (IN.) PER POLE SCHEDULE 10.00 SQ. PER SCHEDULE 0.75 BASE PLATE DIMENSIONS POLE HEIGHT (FT.) TOP DIA. SIZE (IN.) BOTTOM DIA. SIZE (IN.) GAGE MOUNTING HT. (FT.) PER POLE SCHEDULE 4.00 4.00 11 GA. PER POLE HT POLE DIMENSIONS AVPL-SSS- 4" SQUARE STRAIGHT STEEL SERIES **11 GA (.120 STANDARD WALL)** SSS4-1.0 4 " S Q U A R E S T R A I G H T S T E E L P O L E S P E C I F I C A T I O N S NOTES: 1. ORDER LEAD TIMES WILL VARY DEPENDING ON OPTIONS SELECTED. CONSULT WITH YOUR SALES REPRESENTATIVE. 2. DO NOT ERECT POLES W/OUT HAVING FIXTURES INSTALLED. 3. FACTORY-SUPPLIED TEMPLATES MUST BE USED WHEN SET- TING ANCHOR BOLTS. AVPL WILL NOT ACCEPT CLAIMS FOR INCORRECT ANCHORAGE PLACEMENT DUE TO FAILURE TO USE FACTORY TEMPLATES. 4. IF POLES ARE STORED OUTSIDE, ALLPROTECTIVE WRAPPING MUST BE REMOVED IMMEDIATELY UPON DELIVERY TO PRE- VENT FINISH DAMAGE. 5. AVPL IS NOT RESPONSIBLE FOR THE FOUNDATION DESIGN.. STANDARD DBZ BLK WHT GRY GRN OPTION: GALV ARM STYLE SPECIFY (SEE ARM CUTSHEET SPECS) TENON PT23 (23 8" O.D.X4") PT27 (27 8" O.D.X4") OTHER: (SPECIFY) DRILLED DM19 (1@90°) DM28 (2@180°) DM29 (2@90°) DM39 (3@90°) DM49 (4@90°) 1@90 2@180 2@90 3@90 4@90NO. AVPL-SSS 4" SQUARE STRAIGHT STEEL SERIES POLE SHAFT WALL BOLT ANCHORAGE HEIGHT SIZE GAUGE CIRCLE 104-11 10' 4" X 4" 11 9" 3/4" X 18" X 3" 124-11 12' 4" X 4" 11 9" 3/4" X 18" X 3" 144-11 14' 4" X 4" 11 9" 3/4" X 18" X 3" 154-11 15' 4" X 4" 11 9" 3/4" X 18" X 3" 164-11 16' 4" X 4" 11 9" 3/4" X 18" X 3" 184-11 18' 4" X 4" 11 9" 3/4" X 18" X 3" 204-11 20' 4" X 4" 11 10" 3/4" X 24" X 3" 254-11 25' 4" X 4" 11 11" 3/4" X 24" X 3" SSS 4" POLES / CATALOG / POLE SCHEDULE / MOUNTING OPTIONS / FINISH ORDER LOGIC:SERIES POLE SHAFT WALL MOUNTING OPTIONS FINISH HEIGHT SIZE GAUGE DRILLED / TENON ARM STYLE AVPL-SSS - ____ - 4 - 11 - - ________________ - _____________________ - __________ (CHOOSE ONE) EXAMPLE: AVPL-SSS-10-4-11-DM19-XX-GRN-XX ALLOWABLE WIND LOADING (SQ. FT.) **CALCULATIONS ARE BASED ON SUSTAINED WIND FORCES PLUS ADDITIONAL 1.3 WIND GUST** MAXIMUM EPA - SQ. FT Catalog MAX. 100 MPH 90 MPH 80 MPH 70 MPH Number FIXT. WT. 104-11 400 16.9 20.7 26.3 33.6 124-11 400 12.4 16.3 20.6 26.0 144-11 400 10.1 13.0 16.3 20.4 154-11 400 9.1 11.6 14.6 18.1 164-11 400 8.1 10.3 13.0 16.1 184-11 400 6.4 8.4 10.3 14.0 204-11 400 5.0 6.4 8.1 11.8 254-11 350 1.8 3.4 5.7 9.0 POLE SHAFT DRILLED PER FIXTURE REQUIREMENTS: REMOVABLE TOP CAP VARIES DRILLED MOUNT STYLES **OTHER COLORS AND FINISHES AVAILABLE - SEE ACCESSORIES CUTSHEET** STANDARD COLORS AND FINISHES GRN (green)DBZ (dark bronze)WHT (white)BLK (black)GRY (grey)GALV (galvanized) ANCHOR BOLT MINIMUM........3 1 4" MAXIMUM........3 3 4 " BOLT PROJECTION SHAFT: Commercial-quality, hot-rolled, carbon steel tubing with a mini- mum yield strength of 46,000 PSI, conforms to ASTM A500 grade B. ANCHOR BASE: Fabricated from hot-rolled carbon steel plate conform- ing to ASTM A36 meets or exceeds minimum yield strength of 36,000 PSI. All welds shall conform to AWS D1.1. Base plate and shaft is circumferen- tially welded top and bottom. ANCHOR BOLTS: Fabricated from hot-rolled carbon steel bar with mini- mum yield strength of 55,000 PSI. Bolt are fully galvanized and conform to ASTM-F1554 A55. Each bolt is furnished with two hex nuts and two flat washers. BASE BOLT COVER: Two-piece standard full base cover is fabricated from heavy gauge quality carbon steel and pretreated with corrosion inhi- bitors. Provided with S304 stainless steel hardware. Spun and cast alumi- num covers are available. GROUNDING: Provision; 3/8-16 Threaded stud welded to inner shaft wall opposite hand hole. Flat washer and hex nut provided. HAND HOLE: Reinforced 3" X 5" hand hole is located 18" above base. Cover and attachment hardware provided. Location at 90 deg. from drilling. HARDWARE: S304 stainless steel TOP CAP: Removable top cap provided with drill-mount poles. FINISH: TGIC thermoset polyester powder coat finish is electrostatically applied at a 3.0 mil nominal thickness. A five stage metal pretreatment process and sealer provide maximum corrosion resistance. The powder top coat is baked in excess of 400 degrees for supreme endurance. 18.00" POLE HEIGHT REMOVABLE BASE COVER 3.00 X 5.00 HAND HOLE W/ COVER 25' 18' 20' 16' 15' 12' 14' 10' POLE ELEVATION 43827 Division St. Lancaster, CA 93535 Toll free: (844) 770-AVPL Fax: (661) 945-2764 t sales@avpltg.com t www.avpltg.com STL-1 TEMPLATE 10.00 X 10.00 X 0.75 ANCHOR PLATE 8.00-11.00" DIA. BOLT CIRCLE SLOTTED 254-11 350 1.8 3.4 5.7 9.0 DM19 (1@90°) DBZ 184-11 18' 4" X 4" 11 9" 3/4" X 18" X 3" OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 PRELIMINARY SHEET DATES: AUGUST 18, 2014 OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 OW N E R : PR O J E C T : SHEET 20 1 4 E X C E L E N G I N E E R I N G , I N C . JOB NUMBER: c 1411730 TA C O B E L L S6 9 W 1 5 6 1 5 J A N E S V I L L E R O A D MU S K E G O , W I 5 3 1 5 0 SU N D A N C E , I N C . 79 1 5 K E N S I N G T O N C O U R T BR I G H T O N , M I C H I G A N 4 8 1 1 6 PRELIMINARY SHEET DATES: AUGUST 18, 2014 CL CL CL CL CL CL CL CLCL CL CL DEVICE OCB MENU BOARD POWER (1) 3/4" (1) 3/4" DATA (3) 1" - CONDUIT SCHEDULE CLCL CL